Temperature range: -50 up to 800°C

Category: Industrial sensors · Dial thermometers

Specifications by model

CharacteristicValue
GeneralGeneral
DesignEN 13190
Tolerance±1.0% of full scale
Ambient temperature-20…+60°C
Storage temperature-50…+70°C without liquid dampening -20…+60°C with liquid dampening
Over-range limits110% full scale
Stem pressure rating25 bar (Without thermowell)
WeldsTIG argon arc welding
Standard versionStandard Version
Dial diameter100 mm / 150 mm / 250 mm
Span-50 up to 800°C
MountingDirect Bottom connection
Stem size6.0 mm / 8.0 mm / 9.5 mm / 12 mm
Ingress protection ratingIP 65
Stem length150 mm standard up to 3000 mm
ConnectionAdjustable connection
Process connection½" NPT (M) / ½" BSP (M)
MaterialMaterial of construction
Sensing elementInert Gas Filled sensor bulb
Case and bezel materialAISI 304 SS
Stem materialAISI 316 SS
ConnectionAISI 316 SS
DialAluminum, black graduation on white background
PointerMicro-zero adjustable, aluminum, black powder coated
SealsNeoprene / NBR
WindowSheet glass
Filled versionsFilled versions
GlycerineGlycerin
WindowShatterproof safety glass
Damping fluidGlycerin 99.7% / 80% / 60% [Max temperature range limit 100°C]
Silicone oilSilicon Oil
WindowShatterproof safety glass
Seals, safety disc and filling plugNBR / Viton
Damping fluidSilicon oil DC 200 [Max temperature range limit 200°C]
Temperature effectWhen temperature of the measuring system deviates from reference temperature (+20): max ±0.4% / 10K of full scale value.